How to configure Linksys SPA phones with sipX
The following instructions cover the configuration of Linksys's IP phones with sipXecs
Identify the phone's IP address
- Connect the phone to a network with DHCP and power the phone up using the provided power supply.
- Once the phone is up, press the "Configure" button (just below the Envelope button).
- Use the up/down scroll buttons to scroll down to option '8 Network' and press the 'Select' softkey.
NOTE: Make a note of option "2 Current IP" (the current IP address)
Perform a Factory Reset
- If the phone has been used with other systems you may want to factory reset the phone.
- With the phone powered up, press the "Configure" button (just below the Envelope button).
- Use the up/down scroll buttons to scroll down to option '14 Factory Reset' and press the 'Select' softkey.
- Press the "Ok" softkey to confirm.
Connect to the phone's Web User Interface
- Open a Web browser from your PC and enter the IP address of the phone in the Web browser's address field.
- Click Admin Login on the Linksys configuration Web page (there is no default password).
Set the phone to Auto Provision
- In the Web Interface click on Admin Login -> Advanced -> Provisioning Tab
- Change the Profile Rule to read: /spa$MA.cfg
Known Issues
Call Pickup from Park Orbit
*Phones can retrieve from park orbit by dialing *4EXT where EXT is the Park Orbit Extension the call was transferred to.
sipXconfig Template Problem
- Documented in: http://track.sipfoundry.org/browse/XCF-2415
- MOH Setting not set by default.
- MWI Setting not set by default.
- Phone User not set
Useful Links - Configuring MOH and MWI settings for Linksys SPA phones
Workarounds
MWI Setting
- Go into the Admin -> Advanced -> EXT1 setting on each phone and setting Voice Mail Server to be ext@sip.domain.