By default, web access is disabled through the WAN or "Internet" port, but if you want to get access this way, you can enable this through the phone by typing ***, then press *7932#, then *1#, then *1. After that, you can enter the IP address from the previous step into a web browser and access the web interface.
...
You can initiate a manual restart or a reload of the profile on a Linksys ATA device by entering appropriate URLs for the device through a web browser. If an administrative password has been set, you will be prompted to enter the username (usually "admin") and password (see note above to set it, default should be "admin") before the request will take effect. Assuming an IP address for the ATA device of "192.168.1.100, the URLs are:
...
Code Block |
---|
http://192.168.1.100/admin/resync?tftp://192.168.1.200/basic.txt |
If you omit the URL parameter, the device will follow whatever provisioning settings are currently configured on the device.
...