Manual Configuration of an FXO Gateway (MP-
...
114/118/124)
The following describes configuration of an MP-104 FXO gateway with firmware revision 4.60A. Start the Audiocodes gateway configuration by accessing the Audiocodes embedded Web server:
...
- PCM Law Select: Select Mulaw; this must be MuLaw for T1.
- TDM Bus Clock Source: Select Network; this is the clock source.
Audiocodes: Reset to Factory Defaults
- Disconnect the MP-1xx from the power and network cables
- Reconnect the power cable. The gateway is powered up. After approximately 45 seconds the Ready LED turns to green and the Control LED blinks for about 3 seconds
- While the Control LED is blinking, press shortly on the reset button (located on the left side of the front panel); the gateway resets a second time and is restored with factory default parameters
Gateway Default Parameters:
- Default IP Address: 10.1.10.11
- Default Netmask: 255.255.0.0
- Username: "Admin", password: "Admin" (Note: The letter 'A' is capitalized)
...