Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Manual Configuration of an FXO Gateway (MP-114/118/124)

The following describes configuration of an MP-104 FXO gateway with firmware revision 4.60A. Start the Audiocodes gateway configuration by accessing the Audiocodes embedded Web server:

...

  1. PCM Law Select: Select Mulaw; this must be MuLaw for T1.
  2. TDM Bus Clock Source: Select Network; this is the clock source.

Audiocodes: Reset to Factory Defaults

  1. Disconnect the MP-1xx from the power and network cables
  2. Reconnect the power cable. The gateway is powered up. After approximately 45 seconds the Ready LED turns to green and the Control LED blinks for about 3 seconds
  3. While the Control LED is blinking, press shortly on the reset button (located on the left side of the front panel); the gateway resets a second time and is restored with factory default parameters

Gateway Default Parameters:

  • Default IP Address: 10.1.10.11
  • Default Netmask: 255.255.0.0
  • Username: "Admin", password: "Admin" (Note: The letter 'A' is capitalized)

...